Fire Partitions – Keeping the Fire Where It Is

Promat 23/01/2019

fire partitions
compartmentation
fire resistance

Fire partitions are all vertical and horizontal constructions in a building that form a boundary to stop the fire propagation and therefore let the occupants escape safely and the fire brigade to start intervention.

fire partitions in hotels

Keeping the Fire Under Control by Compartmentation

fire partitions in hotels

Any fire will start small and then grow. If sufficient combustible materials and oxygen are available, and no physical barriers limit the fire, it can quickly grow in size and temperature, and will eventually consume a part of the building, the complete building or even multiple buildings.

Fire safety measures aim to prevent such scenarios. It is difficult to control the quantity of combustible materials in a building, as the decoration and use of materials inside the building will often change throughout the life of the building without thoroughly considering fire safety. Limiting the access of oxygen as a fire fighting strategy carries major risks, as toxic gases or combustible gas mixes may develop. For this reason, limiting the propagation of fire through a building is done by dividing the building into fire compartments. While the fire rages inside the compartment, in the remainder of the building the occupants have time to safely escape and the fire brigade has time to enter the building and intervene.

Compartmentation also prevents damaging the building which results to lower rebuilding cost, shorter rebuilding time and longer building lifespan after the fire.

Each fire compartment is surrounded by boundaries that are fire resistant. This means that the boundaries have been designed and tested to avoid spread of fire and hot gases to the adjacent compartment. These boundaries can be:

  • vertical (walls, partition, membranes)
  • horizontal (floors, ceilings, protective membranes).
The performance of the weakest boundary determines the time until the fire spreads to an adjacent compartment. (also consider joints and penetration, fire stopping)
boundary to stop fire propagation
boundary to stop fire propagation

The vertical and horizontal constructions that form a boundary to stop the fire propagation are generally denoted as fire partitions. The location of partitions is determined by the building designer in accordance with fire safety regulations, for example to limit each fire compartment to a certain maximum floor area or to protect an escape route.

Fire Resistance Criteria for Partitions – How Do Partitions Keep the Fire Locked Up?

Partitions shall fulfil one or more of the following criteria for avoiding fire propagation:

  • E: Integrity & Stability – ability to stop flames and hot gases from penetrating.
  • I: Insulation – ability to restrict the temperature rise on the cold side. In most cases, the temperature at the cold surface may not increase more than 140 degrees Celsius on average, or 180 degrees locally, compared to the initial temperature.
  • R: Loadbearing function – ability of a structure to carry loads or actions without collapsing. Only applicable to partitions if the fire compartmentation boundary has also loadbearing functions.

The fire resistance is always expressed in time, usually in classes that are multiples of 30 minutes. For example, a loadbearing compartment floors, that can withstand fire during at least 120 minutes will be “REI120”, and a sandwich (no-loadbearing) partition wall that keeps the flames out and temperatures low during at least 120 minutes will be “EI120”.

The E and I criteria are intended to stop fire propagation. In case of only an “E” (integrity & stability) requirement, the temperature of the unexposed surface can increase without restrictions.  But if the unexposed surface reaches high temperatures, the combustible materials in the adjacent (non-fire) compartment may spontaneously ignite. This would cause the fire to spread to this compartment even before flames or hot gases penetrate the partition. To avoid this, also the “I” (insulation)  requirement is required for fire compartment, escape routes , floors, etc.

In an element classified “EI” or, if loadbearing, “REI”, cold smoke may penetrate through the partition, as only hot gases are considered by the test standards. During a fire, the heat will activate for example intumescent materials in joints and penetration seals and create a tight boundary. But in the stage before the fire reaches the partition, the cold smoke may penetrate through the partition. This will normally not cause fire propagation, but smoke is often harmful to the occupants of a building. Avoiding smoke propagation is done best with products that are tightly fitting together without leaving gaps, preferably combined with a smoke extraction system to provide a way out for the smoke without building up overpressures. (for example PROMASEAL® Sealants)

Types of Fire Partitions

There are several test standards for horizontal and vertical partitions. Each test standard is related to a specific type of partition.

vertical fire partition

Vertical Partitions

vertical fire partition

Non-loadbearing partition walls are often brick or concrete walls, sandwich partitions or shaft walls. In some cases, the existing walls need upgrading to become a fire partition or to increase the fire resistance rating asked by the local regulation or by the specifier. Even loadbearing walls, such as concrete walls, could need upgrading to increase the fire resistance.

Depending on the structural layout of a wall, its deformation during fire can be significant. Partition elements, and particularly fire protection materials, have to accommodate these deformations while continuing to perform.

For this reason, fire protection boards must always be tested in the relevant application. Joint finishings as tested shall be applied also in practice to make sure that integrity is maintained during fire.

The deflection is also strongly dependent on the height and width of the test specimen. Therefore, the scope of the test report or certificate always must clearly state the height and width limits allowable in practice. To meet the market requests, high rise partition walls can be either tested at their actual height on some furnaces, or a calculation can be done, based on specific codes for extrapolation to increased heights and the results are written down in an assessment made by a notified body.

firestopping for walls
firestopping for walls

Most partition walls contain interruptions, such as pipe and cable penetrations that fully penetrate the wall but also interruptions on one side of the wall such as electricity sockets. Such interruptions are a weak spot when it comes to fire resistance. Promat walls are tested including solutions for sockets and other common interruptions, and we offer a wide range of penetration seals for cable and pipe penetrations.

All the partitions are tested in standard configurations, but there are always differences between the tested specimen and the application on site. Some of these differences are covered by direct fields application or by engineering judgments and assessments, but it is often necessary to do specific tests. For example, the corners of the walls, the connections between wall and slab, sprinkler supports or shelves hung on the walls must be fire tested.

All these "details" play a key role in fire safety and must not be underestimated. For years we have been at the forefront in testing complex and real-world configurations and can provide several solutions for each specific case.

A critical element of a non-loadbearing partition wall in practice is the connection of the partition wall to the ceiling or floor above. This connection needs to provide for some movement due to possible deformations of the partition wall as well as the floor above during fire, but at the same time remain closed against fire. We developed specific head of wall solutions to make sure that this movement is accommodated but the fire does not propagate.

CHECK OUR FIRE PARTITION SOLUTIONS >
Horizontal partitions

Horizontal Partitions

Horizontal partitions

Horizontal partitions or ceilings can be tested in different ways, and this determines strongly how they will perform in practice. For this reason, it is necessary to select a fire protection system that is tested in a configuration that fits the needs.

In most national building regulations, there are requirements for “fire from below”: propagation from the compartment below to the compartment above. In some cases, there are also rules for “fire from above”: propagation from the compartment above to the compartment below. Both situations will affect the construction in very different ways, so they need to be tested separately.

The mostly used horizontal compartmentation are:

  • Incombustible or low combustible ceilings
  • Independent ceiling (ceiling membrane)
  • Suspended ceilings, which give a contribution to the fire resistance of load bearing elements (protective systems)
  • Ceiling as component of a fire rated roof/floor constructions, with or without cavities.
READ MORE ABOUT FIRE-RATED CEILINGS SYSTEMS >